About Dp50rb
About Dp50rb
Blog Article
The person will not be permitted to open up the covers and panel of the process, neither Be aware: machine disassemble is allowed. To ensure the procedure efficiency and protection, only Mindray engineers or engineers authorized by Mindray can conduct upkeep.
Check out Keep in mind my option and click on OK in the dialog box over to affix activities more quickly in the future! Many thanks for viewing Roblox
After you stop the scanning plus the image capture, you'll want to energy off the method and disconnect the procedure with the AC ability source, then pull out AC power cables. Web page 109: Battery Connecting Board
Permits use of numerous scanned angles to type a single image, causing Increased contrast resolution and improved visualization
The DP-50 Pro is undoubtedly an impressive, higher-general performance Ultrasound System engineered that can assist you get the insights you may need. The Process’s potent motor and substantial-speed processing give superb image high quality and a whole information administration Resolution.
5.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy Test Action: Do adjustments as the way in screening the most depth. File the distance by 20mm each section to the longitudinal targets line using the measurement caliper; Find the value with the best mistake (to 20mm), compute the precision using the formula underneath The measurement caliper ought to be positioned for the upper edge of the focus on, Be aware:... Site 79 Transverse geometric positioning precision Test Move: Deal with the scan surface area of your phantom with drinking water or pair gel, gently Speak to the probe While using the scan surface Modify the depth, creating the transverse targets to be displayed within the image. Regulate the main focus point for being posited beside the transverse targets (the common is not distinct) Modify parameters like acquire, TGC, generating Just about every transverse targets for being Evidently shown. Web site 80 five.5.two.four Blackout Spot Take a look at Phase: Address the scan surface of the phantom with water or couple gel, Carefully Make contact with the probe Along with the scan area Modify the depth at a reduce value, and established the main target at the nearest spot to the scan floor. Lower the worth of parameters like AP, Obtain until the qualifications noise just can be seen. Web site 81: Application Upgrade And Routine maintenance
Be aware: Before inserting the connector into your probe port, inspect the connector pin. In case the pin is bent, don't utilize the probe till it's been inspected / fixed / changed. Installing Peripherals For that versions of the supported peripherals, remember to check with “two.
By continuing your visit on our Web-site, you might be consenting to our use of cookies. Having said that, you'll be able to alter your cookie options at any time. Cookie desire Accept and Progress
While in the midst of hurricane period, crisis management officials are tasked Together with the essential mission of hurricane catastrophe preparedness.
Find superior diagnostic information and facts via prolonged watch with the anatomical composition on all linear probes
This manual could referring to facts shielded by copyright or patents and doesn't convey any license under the patent rights or copyright of Mindray, or of Other folks. Web site 9: Assertion
Notice: Be certain that you might pull out and drive in to the IO board sockets vertically when pulling out and assembling the IO board assembly within the placement on the deal with. Eliminate panhead screws with washers M3X6 (4) used to secure the IO board, then you might consider out the IO board. Web site 116 Get rid of panhead screws with washers (two M3X6) which happen to be mounted on the primary device, get out the upper baffle after which pull out two cables connecting the leading board to the ability module assembly.
Get an entire and prolonged look at in the anatomical composition by way of panoramic imaging coupled with velocity indicator and forward/backward scan capability making scanning less of a challenge, smoother and a lot more controllable.
three. Click on the upper icon during the monitor (prompts “Update” if you put the cursor on it), the update stage is completed, if fails, you should send to R&D center. Determine 6-one Primary Check Upkeep Screen 4. Right after update is productive, restart the equipment soon after electrical power off to create the information successful. HDD Partition ... Page 91 structured report similar knowledge file and DICOM viewing software Report report template obd.bin OBD data file Edition.txt Model file Remark Remark file AnatomyImage Anatomical images Measurement Measurement library Doppler software and connected boot configuration most important file and plug-ins, distant desktop server Multilanguage string file exe videoplay.
Functionality Check five.5.one Examination System Resolution Detection depth Geometric Posture Precision Blackout place test File the Examination pictures five.5.2 Exam Content The graphic applied here is just for reference, keep on with the impression influence in the actual Notice: problem. Necessities: Show: established the contrast and brightness for the scientific software worth (or even the default status) Procedure atmosphere: dark place, simulating the scientific application setting. Web site Dp50rb 76 In condition which the transverse resolution testing targets are horizontally shown, report the small length of two targets that may be Evidently recognized. Repeat the operation over with the transverse resolution testing targets at other depths. As proven in determine down below. Axial resolution ... Website page 77 When utilizing the convex probe, preserve the transverse resolution testing targets to NOTE: be shown close to the midline. When employing a linear probe with steer perform, don't turn on the steer function when complete the transverse resolution examination. Zoom in the area in which the targets Situated if vital. The diameter from the target place at a particular depth is equivalent on the transverse resolution for the depth. Site 78 5.